Edward writes and edits Induqora's coverage of industrial automation and control, including PLC programming, industrial networking, OT cybersecurity, process control and the regulation that shapes the automation industry.
Covers: PLC programming · Industrial networking · OT cybersecurity · Process control · Automation regulation
A standard 9-volt multimeter ohm check routinely passes a failing 3-phase motor that trips a VFD on ground fault two seconds later. Master IEEE Std 43-2013 insulation resistance, 40°C temperature correction, PI/DAR curves, winding unbalance limits, and ANSI/EASA AR100 rewind-vs-replace economics.
Replacing noisy VFD-driven motor bearings only to watch them howl again 90 days later with washboard fluting is one of industrial maintenance's most frustrating cycles. Learn the physics of EDM shaft currents, NEMA MG 1 Part 31 reflected wave limits, output filter selection, and 360-degree shield grounding.
Replacing a failed VFD without verifying the power stage, motor cable insulation, and shelf-spare capacitor condition frequently destroys the replacement drive on first start. Master the 12-point static multimeter diode test, official DC bus capacitor reforming schedules, and IGBT failure forensics.
Electric motor systems consume roughly 70 percent of industrial electricity, and electricity accounts for over 95 percent of a continuous-duty motor's 10-year cost. Review official IEC 60034-30-1 efficiency tables, EU 2019/1781 and US DOE 10 CFR 431 mandates, SynRM vs. PM architectures, and worked ROI math.
Overheated control panels silently halve PLC, VFD, and power-supply lifetimes long before thermal trips stop production. Apply IEC 60890 heat-balance equations, NEMA 250 vs. IEC 60529 enclosure data, component watt-loss tables, and worked CFM/BTU cooling calculations to engineer reliable cabinets.
Variable frequency drives save massive energy on industrial pumps and fans, but six-pulse diode rectifiers inject 5th, 7th, 11th, and 13th harmonic currents that overheat transformers and trip breakers. Use official IEEE 519-2022 tables, worked PCC sizing math, and filter benchmarks to design compliant drive installations.
Why industrial PLC CPUs, CNC printed circuit boards, and operator HMIs fail after 8 to 15 years in service — from electrolytic capacitor ESR rise and SRAM battery decay to backplane fretting and ESD latency — plus how to structure preventive MRO.
Multi-axis CNC racks share a common DC link across power supplies, spindle amplifiers, and feed servo drives. Learn how pre-charge circuits, regenerative stages, bus ripple, and spindle orientation loops work — and how to isolate faults safely.
CISA advisory ICSA-26-323-03 highlights CVE-2026-125132, an unpatched integer underflow in the lightweight C library libumqtt (<=1.1.1) used in embedded Linux gateways and IIoT devices — underscoring why SBOM tracking and broker isolation matter.
CISA issued ICS Advisory ICSA-26-323-01 on November 19, 2026 warning of a race condition (CVE-2026-126088) in Autonomy Logic OpenPLC Runtime versions 4.2.4 and earlier that lets unauthenticated remote attackers create admin accounts. Version 4.3.0 fixes the flaw.
The EtherCAT Technology Group has published ETG.1800 v1.0, showing how 25 existing EtherCAT functions satisfy IEC 62443-3-3 Security Level 2 without protocol or hardware changes roughly one year ahead of full EU Cyber Resilience Act enforcement.
The International Federation of Robotics reports that global operational factory robots reached a record 5 million units after 600,000+ new installations in 2025, while global manufacturing robot density climbed to 152 units per 10,000 employees in November 2026 data.